Advantages
Time saving: save 15-30 min comparing with agarose beads.
Simple operation: Magnetic separation and centrifugation-free.
High protein loading capacity.
High specificity.
Product Use Citations
Customer Product Validation(2)
Overexpression of Parkin reduced SeV-induced activation of the IFN-, ISRE and NF-κB promoters. HeLa cells were co-transfected with the indicated expression plasmids and luciferase reporter constructs driven by promoter of gene encoding IFN-β(A), ISRE (B), or NF-κB (C). pRSV/lacZ was used as an internal control. Twenty-four hours after transfection, cells were infected with Sendai virus(SeV) for 24 h, and then lysed for luciferase assays (upper panel) and immunoblotting assays (lower panels).
Immunoprecipitation for Myc-tag Fusion protein in HEK239T
1: 20% input
2: bimake anti-Myc magnetic beads flow through
3: bimake anti-Myc magnetic beads
4: bimake anti-Myc affinity gel flow through
5: bimake anti-Myc affinity gel
Price Comparison
Description
Anti-Myc magnetic beads kit is based on hydroxyl magnetic beads covalently coupling with high quality mouse IgG1 monoclonal antibody. With high loading of Myc-tagged protein (more than 0.6 mg protein/mL) and high specificity, it is recommended to use for co-immunoprecipitation and protein purification.
Properties
| Antibody isotype | Mouse IgG1 |
|---|
| Antibody purification | Protein A purified |
|---|
| Application | Immunoprecipitation and protein Purification |
|---|
| Recommended volume | IP: 20 μL beads for 200 μL crude protein solution |
|---|
| Binding capacity | Minimum 0.6 mg protein eluted per ml of magnetic beads |
|---|
| Shipped in | Blue ice |
|---|
Storage
Store at 2-8°C for 2 years. DO NOT freeze or centrifuge Magnetic Beads.
Protocol
Trouble Shooting
| Problem | Possible Reason | Suggested Improvement |
|---|
| High background | Nonspecifically binding of proteins to the antibody, megnetic beads or EP tubes | Pre-clear lysate to remove nonspecific binding proteins. After suspending beads for the final wash, transfer the entire sample to a clean EP tube and then centrifugation. |
| Washing times are not sufficient. | Increase the number of washes. Increase duration time of washes. |
| No signal is observed. | Myc tagged protein is not expressed in the sample. | Make sure the protein of interest contains the Myc sequence. Prepare the fresh lysate. Use appropriate protease inhibitors. |
| Incubation times are inadequate. | Increase the incubation times. |
| Interfering substance is present in sample. | The lysate may contain high concentrations of dithiothreitol (DTT), 2-mercaptoethanol, or other reducing agents. Excessive detergent concentration may interfere with the antibody-antigen interaction. |